Performance advantages:
1) Triple dynamic password to protect data security
2) System upgrade interface, convenient for upgrade and maintenance
3) Independent movement with accuracy and stability
4) Safe and effective overcurrent protection
5) Waterproof and dustproof controller with good leakproofness
6) With low-power design, the battery can be used for a year
Technical indicators:
Level of measurement: 1.5
LCD display resolution: 0.1 m3 (100 liters)
Working voltage: DC4.8V - 6.3V (4 alkaline batteries)
Quiescent current: ≤20 uA
Data retention: > 10 yearse
Product model |
Technical indicators |
JGD6S-ML-G |
JGD10S-ML-G |
JGD16S-ML-G |
JGD25S-ML-G |
JGD40S-ML-G |
JGD65S-ML-G |
JGD100S-ML-G |
Qmax (m3/h) |
10 |
16 |
25 |
40 |
65 |
100 |
160 |
Qmin (m3/h) |
0.06 |
0.1 |
0.16 |
0.25 |
0.4 |
0.65 |
1 |
The total pressure loss (Pa) |
250 |
250 |
375 |
375 |
375 |
500 |
500 |
Cycling volume (dm3) |
4 |
10 |
10 |
20 |
20 |
40 |
40 |
Measuring range (m3) |
0~99999.999 |
0~999999.99 |