Customization: | Available |
---|---|
Install: | Horizontal |
Medium Temperature: | Cold/Hot Water |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Product Overview:
LXS NB-loT smart water meter adopts mechanical base meter. According to the customer's needs can be matched with magnetic/no magnetic/dry/wet and other schemes, which inte grates data storage, remote communication and local com munication, and has the advantages of ultra-low power consumption, high accuracy, high reliability and high stability. It can be widely used in residential units, buildings and other systems.
2. Main Advantages:
3. Dimensions:
4. IoT Smart Water Solution:
5. Technical Parameters:
Name | LXS NB-IoT Smart Water Meter | |||||
Accuracy class | 160 / 125 / 100 / 80, 100 by default | |||||
Range ratio | Class 2 | |||||
Base meter material | Iron / Copper / Stainless steel / Plastic | |||||
Nominal diameter (mm) | 15 | 20 | 25 | |||
Q3(m /h) Permanent flow | 2.5 | 4 | 6.3 | |||
Q1(L/h)Minimum flow | 25 | 40 | 63 | |||
Start-up flow (L/h) | 6 | 8 | 10 | |||
Pressure loss level | Δp 63 | |||||
Pulse equivalent | 1L/10L | |||||
Key | Infrared / Magnetic key | |||||
Data communication | Remote | NB-IoT, Goldcard security agreement or customer defined agreement, Goldcard security agreement by default | ||||
Local | Infrared interface, Goldcard security protocol or CJ/T 188 protocol | |||||
Data communication | 1.Half-hour water usage log, lasting for one month 2.Monthly cumulative log, lasting for 24 months 3.10 abnormal alarm logs (magnetic interference, under-voltage, reverse flow, etc.) 4.25 system operation and communication logs |
|||||
Maximum allowable working pressure | 1.0MPa | |||||
Temperature level | T30 | |||||
Sensitivity level of upstream and downstream flow field | U0/D0 | |||||
Environment and electromagnetic level | Class B / E1 | |||||
Working power supply | Battery power supply DC 3.6V, service life for more than 8* years | |||||
Degree of protection | IP68 | |||||
Storage temperature | 0°C~+55°C, ≤100%RH | |||||
0ne -time meter reading success rate | ≥99% | |||||
Standard basis | 1. GB/T 778-2018 Drinking Cold Water Meter and Hot Water Meter 2. JJG 162-2019 Cold Water Meter 3. GB/T 778-2007 Measurement of Water Flow in Fully Charged Closed Conduits-Meters for Cold Potable Water and Hot Water |
|||||