Tbqs-DN150-ANSI 150 Industrial and Commercial Tbqs Quantometer G10 to G1600

Product Details
Customization: Available
Accuracy: >±1%
Main Application: Nature Gas
Manufacturer/Factory, Trading Company
Gold Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Public Company
Management System Certification
ISO 9001, ISO 14001
Find Similar Products
  • Overview
  • Product Overview
Overview

Basic Info.

Model NO.
TBQS-DN150-ANSI 150
Application
Energy Metering
Type
Turbine Flow Meter
Measuring Media
Gas
Certification
CE, ISO, PED
Gas Temperature
-25~+60
Storage Temperature
-30~+60
Operating Pressure
16 Bar and 20 Bar
Protection Class
IP67
Meter Housing/Turbine Rotor
Aluminum Alloy
Meter Index Head
Synthetic Material (Standard).Optional Aluminum
PED Approval
Hpi/222-103-Q-Oi
Counter
Eight-Digit Mechanical Roller Counter
Pulse Output
1 Lf-Pulser (Reed Contact) and L Anti-Tampering Co
Reproducibility
<0.2 %
Trademark
Goldcard (TANCY)
Origin
China
HS Code
9028109000
Production Capacity
3, 000, 000 PCS/Year

Product Description

Product Overview

1. Applications:

The TBQS Quantometer is a turbine meter for operational natural gas-volume measurement and for other non-aggressive gases such as propane, butane, air, carbon dioxide,or inert gases used in internal and controlling processes of various types, especially in industrial thermoprocessing facilities.

2. Features:

  • Meter size: G10 to G1600
  • Nominal sizes: From DN25 (1") to DN200(8")
  • Measuring range: 1:10 or 1:20
  • Flow rates: From 2 to 2500 /h
  • Pressure class: PN16 and ANSI 150
  • Maintenance free based on permanent lubrication of the ball bearings
  • Standard engineered polymer material index head optional aluminum index head Rotating index head (355°)
  • Horizontal and vertical mounting position
  • Anodized high strength aluminum meter body
  • Optional manual lubrication of the ball bearings by means of oil pump
  • Recommended straight inlet pipe ≥3DN and outlet pipe ≥2DN
  • Approval according to PED (PED2014/68/EU)

3. Operating Principle:

The Quantometer is a turbine gas meter that registers the operating volume using an eight-digit mechanical counter. Via pulses the operating volume can be transferred to an electronic volume corrector and converted to nommal or standard conditions.
The TBQS Ouantometer is a volume flow meter. The flow of the gas to be measured causes the turbine rotor to rotate. The gas flows narrowed on an annular cross section, is accelerated and directed onto the smooth-running Aluminum rotor. The number o rotations is proportional to the measured gas volume; the frequency of rotations is proportional to the actual gas flow. The rotation of the rotor is connected to a speed-reducing gear train and transmitted via a magnetic coupling from the gas pressurized area to the adjustable 8-digit roller counter in the atmospheric environment.
The actual volume flow can be transmited to electronic volume correctors or data loggers via low frequency (LF-) pulses generated by Reed contacts. In the meter's index head is also located an anti-tampering contact.
The rotation of the rotor can be scanned additionally with one freguency (HF-) sensor as an option. The HF-sensor signal allows the determination of the actual gas flow in high-resolution.

4. Technical Parameters:

ltems TBQS Quanto Meter
Gas Temperature -25°C to +60°C
Ambient Temperature -25°C to +60°C
Storage Temperature -30°C to +60°C
Operating Pressure 16 bar and 20 bar
Protection Class IP 67
Meter Housing Aluminum alloy
Turbine Rotor Aluminum alloy
Meter Index Head Composite(optional:aluminum)
Meter Index Head Synthetic material (standard).optional Aluminum
PED-Approval Hpi/222-103-Q-OI
ATEX-Approval Ex-Zone 1
Reproducibility <0.2 %
Overload up to 1.25 Qmax
Pressure Change Rate <0.35 bar/s
Counter Eight-digit mechanical roller counter
Meter index Head Standard synthetic material. aluminum as option
Pulse Output 1 LF-pulser (Reed contact) and l anti-tampering contact
Option:additional 1 HF-pulser
Pressure 1 connection with 1/4"NPT-thread
Temperature 1 thermowell with G 1/4"-thread (option)

5.  Error Limits:

The TBQS Quantometers are all initially calilbrated within the specified measurement errors. Reduced measurement errors limits are optionally available.
The TBQS Quantometers are manufactured with large measurement ranges due to the precision machining of the parts and a reproducible assembly process.
The standard calibrated measurement range for the TBQS is 1:10 or 1:20 under atmospheric conditions.

6. Sizing Table:
Tbqs-DN150-ANSI 150 Industrial and Commercial Tbqs Quantometer G10 to G1600
7. Meter Design:Tbqs-DN150-ANSI 150 Industrial and Commercial Tbqs Quantometer G10 to G1600
1) Pressure containing housing
2) Turbine wheel
3) Mechanical counter/index
4) Magnetic coupling
5) Inlet flow straightener
6) Measuring cartridge
7) Gear train

8. Connections:

TBQS Quantometer housings are manufactured without flanges as a "sandwich" design to be installed between the two inlet and outlet pipe flanges on a standard basis with raised face (RF) flanges according to DIN/EN 1092-1 Or ANSI B 16.5 for class 150 with a maximum operating pressure of 20 bar/ 2,0 MPa. The TBQS DN 25 M" is designed as flange version with threaded
holes or as a threaded pipe version with a thread of G1".
Tbqs-DN150-ANSI 150 Industrial and Commercial Tbqs Quantometer G10 to G1600



 