Customization: | Available |
---|---|
Kind: | Intelligent Gas Meter |
Diameter: | <25mm |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type | JGM10S-G | JGM16S-G | JGM25S-G |
Meter Size | G10 | G16 | G25 |
Measuring Range | (0.1~16) m3/h | (0.16~25) m3/h | (0.25~40) m3/h |
Communications | GPRS / Zigbee / wM-BUS | ||
Standard temperature for volume output | 15ºC (Other standard temperature on request ) | ||
Standard pressure for volume output | 1013.25mbar | ||
Accuracy class | 1.5 | ||
Measurement resolution | 0.1 L (0.0001 m3) | ||
Measuringaccuracy | Qmin≤Q<Qt, -3%≤E≤+3% Qt≤Q≤Qmax, -1.5%≤E≤+1.5% |
||
Operating temperature range | -25ºC to 55ºC | ||
Max. operating pressure | 50bar (Valve operation up to 0.15bar ) | ||
Max. pressure drop | < 2.5 mbar at Qmax | ||
Ingress protection | IP65 | ||
ATEX | EX II 3C Ex ic IIA T3 Gc (Zone 2) | ||
Measured gas type | 2nd Family Group H and L (EN 437) | ||
Valve | Compliancy with EN16314 | ||
Maximum leakage for the valve | 0.001 m3/h at 0.05bar | ||
Display | Matrix LCD ( with backlight) | ||
Display resolution | 9 data bits, including 4 decimal places | ||
Battery Life | ≥15 years |